Specifications
| MANUFACTURE | Bitmain |
| MODEL | Antminer L9 Hyd |
| ALGORITHM | Scrypt |
| POWER | 5670±5%W |
| HASHRATE | 27±3%Th/s |
| POWER RATIO | 210±5%J/Th |
| NOISE LEVEL | 50 dB |
| NETWORK CONNECTION MODE | RJ45 Ethernet 10/100M |
| SIZE WITHOUT PACKAGE | 509×481×87mm |
| SIZE WITH PACKAGE | 710×640×220mm |
| NET WEIGHT | 19.1kg |
| GROSS WEIGHT | 23.2kg |
| PHASE | 3 |
| INPUT VOLTAGE RANGE | 380~415V |
| INPUT FREQUENCY RANGE | 50~60Hz |
| MAXIMUM INPUT CURRENT | 12A |
| POWER PORT | LP34 |
| INLET COOLANT TEMPERATURE | 20~50℃ |
| COOLANT FLOW | 8.0~10.0L/min |
| COOLANT PRESSURE | ≤3.5 bar |
| WORKING COOLANT | Antifreeze/Pure water/Deionized water |
| COOLANT PH VALUE | Antifreeze: 7.0~9.0 | Pure water: 6.5~7.5 | Deionized water:8.5~9.5 |
| DIAMETER OF COOLANT PIPE CONNECTOR | OD14mm |
| STORAGE TEMPERATURE | -20~70℃ |
| OPERATION HUMIDITY(NO CONDENSATION) | 10%~90%RH |
NOTE
1. The hashrate value, power on wall, and power efficiency on wall are all typical values. The actual hashrate value fluctuates by ±3%, and the actual power on wall and power efficiency on wall fluctuate by ±5%.
2. Inlet coolant temperature.
3. Caution: Wrong input voltage may cause server damaged.
4. For detailed working coolant use and maintenance instructions, please refer to "ANTSPACE HK3 Water Cooling Container & Dry-Wet Tower Product Manual", Chapter 9, Article 3, Point 6, "Maintenance of Coolant"!